Journal of Dentistry
Volume 38, Issue 3 , Pages 182-190, March 2010

Quantifying and qualifying surface changes on dental hard tissues in vitro

School of Dental Sciences, Newcastle University, Framlington Place, Newcastle-upon-Tyne, Tyne and Wear NE2 4BW, United Kingdom

Received 24 September 2009; received in revised form 11 December 2009; accepted 6 January 2010. published online 15 January 2010.

Abstract 

Introduction

Tooth surface loss (TSL) is an increasingly recognised problem. We are therefore seeing an increase in the number and complexity of in vitro studies investigating factors that modify effects at the tooth surface.

Aim

The aim of this paper is to provide a narrative review that illustrates the more commonly used in vitro methods (both historical and contemporaneous) that are available for measuring surface loss and surface change.

Method

An initial search (March 2009) was carried out using Scopus abstract and citation database with the keywords ‘dental’ AND ‘erosion OR abrasion’ ANDsurface change OR surface loss’ AND ‘vitro’ (1975–2009). This resulted in 69 papers which were reviewed and the methods critically appraised. Bibliographic material from the papers was then used in order to find other appropriate sources.

Results

It is clear that tooth surface change is a complex process that can be measured in a variety of ways. No single technique provides a comprehensive assessment of the remaining tooth surface, and each technique suffers its own limitations. What is also clear is that way in which surface change is reported by each of the techniques gives little information relating to how the surface may change in the immediate future.

Conclusion

Despite a variety of available in vitro tests for measuring surface changes, the roughness average (Ra) is still the main reported measurement within dental studies. Using the same set of profilometric data, it is proposed that additionally reporting bearing area parameters will allow a further and more meaningful description of the surface quality.

Keywords: Tooth surface, Wear, Measurement, Roughness, Bearing curve, In vitro

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0300-5712(10)00014-X

doi:10.1016/j.jdent.2010.01.002

Journal of Dentistry
Volume 38, Issue 3 , Pages 182-190, March 2010