Journal of Dentistry
Volume 37, Issue 12 , Pages 978-983, December 2009

Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crowns

Department of Prosthetic Dentistry, Regensburg University Medical Center, Franz-Josef Strauss Allee 11, D-93042 Regensburg, Germany

Received 20 April 2009; received in revised form 6 August 2009; accepted 11 August 2009. published online 19 August 2009.

Abstract 

Objectives

The aim of this study was to evaluate the in vitro behaviour of all-ceramic zirconia molar crowns in regard to different core designs and marginal fit.

Methods

Identically shaped methacrylate molars were prepared according to the ceramic restoration directives resulting in a 1-mm deep circular shoulder preparation. They were embedded in polymethylmethacrylate resin after covering their roots with a polyether layer to simulate periodontal mobility. The crown cores were made of yttria-stabilized zirconia veneered with a corresponding veneering ceramic. The crowns were divided into 5 groups (n=8) which differed in core design and cement gap thickness: #1: simple core, 40μm cement; #2: core with minimal occlusal support, 40μm cement; #3: core with optimized cusp support, 40μm cement; #4: core with optimized cusp support, 30μm cement; #5: core with optimized cusp support, 10μm cement. All crowns were cemented with zinc oxide phosphate cement and thermo mechanically loaded (1.2×106×50N; 6000×5°C/55°C) with identical metal ceramic restorations as antagonists. Crown failures were monitored and described. Area and direction of the chipping failures of the veneering ceramic were documented by means of scanning electron micrographs.

Results

All core designs showed chipping during chewing simulation with different numbers (defect areas). #1: 6 chippings (8.1mm2); #2: 2 chippings (3.5mm2); #3: 2 chippings (2.1mm2); #4: 3 chippings (5.7mm2); #5: 3 chippings (7.3mm2).

Conclusions

An optimized core design reduced number and surface area of occurring chippings. A variation of the gap thickness showed no significant influence on the in vitro performance.

Keywords: Zirconia, Core design, Chipping

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0300-5712(09)00201-2

doi:10.1016/j.jdent.2009.08.003

Journal of Dentistry
Volume 37, Issue 12 , Pages 978-983, December 2009