Journal of Dentistry
Volume 37, Issue 9 , Pages 712-717, September 2009

Restoration techniques and marginal overhang in Class II composite resin restorations

College of Dental Science, Department of Preventive and Restorative Dentistry, Radboud University Nijmegen Medical Centre, The Netherlands

Received 6 March 2009; received in revised form 19 May 2009; accepted 20 May 2009. published online 01 June 2009.

Abstract 

Objectives

The objective of the study was to compare in vitro interproximal overhang formation of Class II composite resin restoration when using different matrix systems.

Methods

240 lower left molar phantom head teeth with an MO-preparation were divided into 12 groups (n=20). In six groups a circumferential matrix (Tofflemire X-thin matrix, HaweNeos 1001-c, SuperCap) was used, combined with either a hand-instrument (PFI49 or OptraContact) or separation ring (Composi-Tight Gold). In the other six groups two sectional matrix systems were used (flexible and dead-soft), with three separation rings (Composi-Tight Gold, Contact Matrix, Palodent BiTine). Matrices were secured with wooden wedges and preparations were restored with composite resin Clearfil AP-X (Kuraray) placed and polymerized in increments. After matrix removal overhang was measured on a standardized digital macroscopic image in mm2. For analysis a multiple linear regression model was used.

Results

Use of circumferential matrices resulted in less overhang than sectional matrices (−0.85mm2, p<0.001). A flexible matrix led to less overhang than dead-soft matrices (0.54mm2, p<0.001), and no difference was found between straight and pre-contoured matrices (p=0.945). The insertion of the OptraContact resulted in a much increased overhang of 2.54mm2 (p<0.001). The Composi-Tight Gold and the Contact Matrix System rings resulted in less overhang, −0.69 and −0.68mm2, respectively (both p<0.001), whereas the Palodent BiTine ring did not.

Conclusions

Use of circumferential matrices or sectional flexible matrices resulted in the least marginal overhang when combined with a Contact Matrix separation ring or a Composi-Tight Gold ring.

Keywords: Interproximal overhang, Class II, Composite resin restoration

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0300-5712(09)00131-6

doi:10.1016/j.jdent.2009.05.025

Journal of Dentistry
Volume 37, Issue 9 , Pages 712-717, September 2009