Journal of Dentistry
Volume 37, Issue 11 , Pages 813-819, November 2009

Four-year clinical performance and marginal analysis of pressed glass ceramic inlays luted with ormocer restorative vs. conventional luting composite

  • Norbert Krämer

      Affiliations

    • Department of Pediatric Dentistry, University Medical Center Carl Gustav Carus, Fetscherstraße 74, 01307 Dresden, Germany
  • ,
  • Christian Reinelt

      Affiliations

    • Private Practice, Nuremberg, Germany
  • ,
  • Gert Richter

      Affiliations

    • Department of Prosthetic Dentistry, University Medical Center Carl Gustav Carus, Fetscherstraße 74, 01307 Dresden, Germany
  • ,
  • Roland Frankenberger

      Affiliations

    • Department of Operative Dentistry and Endodontology, University of Marburg, Georg-Voigt-Str. 3, 35039 Marburg, Germany
    • Corresponding Author InformationCorresponding author. Tel.: +49 6421 5863240; fax: +49 6421 5863245.

Received 18 February 2009; received in revised form 31 March 2009; accepted 6 April 2009. published online 15 April 2009.

Abstract 

Objectives

The aim of the present study was to evaluate the ormocer Definite (Degudent, Hanau, Germany) as resin luting cement.

Methods

In a controlled prospective clinical study, 57 Cergogold (Degudent) all-ceramic inlays were placed in 24 patients by four dentists. The restorations were luted with two different systems (MD=Definite Multibond+Definite; SV=Syntac+Variolink Ultra, Ivoclar Vivadent, Liechtenstein) without lining. At baseline, after 12, 24, and 48 months, restorations were examined according to modified USPHS scores and criteria.

Results

One patient including three restorations missed the 4 years recall (dropout). After 48 months of clinical service, four restorations in four patients (three luted with Definite, one with Variolink) failed due to inlay fracture (n=3) and tooth fracture (n=1), all other fillings were clinically acceptable (survival rate 93.3% for Definite vs. 95.2% for Variolink; Kaplan–Meier algorithm). Except for the rate of hypersensitivity at baseline (MD: 27%; SV 0%; p<0.05), no differences were evident between the luting cements at any recalls (Mann–Whitney U-test; p>0.05). Between the four recalls, a statistically significant deterioration was detected for both groups regarding the criteria marginal adaptation, filling integrity (cracks/chippings/fractures), and tooth integrity (Friedman test; p<0.001). After 4 years, mainly distinct deterioration with marginal fractures or chippings in proximal and marginal areas of the inlays were observed. No differences were found for surface roughness, color matching, and proximal contact (p>0.05).

Conclusions

For luting of ceramic inlays, only slight differences between the two luting systems were detectable.

Keywords: Glass ceramics, Clinical trial, Ormocer, Resin composite, Adhesives

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0300-5712(09)00078-5

doi:10.1016/j.jdent.2009.04.002

Journal of Dentistry
Volume 37, Issue 11 , Pages 813-819, November 2009