Journal of Dentistry
Volume 37, Issue 1 , Pages 65-75 , January 2009

Quantification of all-ceramic crown margin surface profile from try-in to 1-week post-cementation

  • Melissa-L. Good

      Affiliations

    • Health and Healthcare Research Group, School of Medicine and Dentistry, Queen’s University Belfast, Grosvenor Rd., Belfast BT12 6BP, UK
    • Corresponding Author InformationCorresponding author. Tel.: +44 28 9063 4262; fax: +44 28 9043 8861.
  • ,
  • Christina A. Mitchell

      Affiliations

    • Health and Healthcare Research Group, School of Medicine and Dentistry, Queen’s University Belfast, Grosvenor Rd., Belfast BT12 6BP, UK
  • ,
  • Maria R. Pintado

      Affiliations

    • School of Dentistry, University of Minnesota, Minneapolis, MN, United States of America
  • ,
  • William H. Douglas

      Affiliations

    • School of Dentistry, University of Minnesota, Minneapolis, MN, United States of America

Received 2 June 2008 ,Revised 19 September 2008 ,Accepted 19 September 2008.

References 

  1. Loë H. Reaction of marginal periodontal tissues to restorative procedures. International Dental Journal. 1968;18:759–778
  2. Walton JN, Gardiner FM, Agar JR. A survey of crown and fixed partial denture failures: length of service and reasons for replacement. Journal of Prosthetic Dentistry. 1986;56:416–420
  3. Goldman M, Laosonthorn P, White RR. Microleakage—full crowns and the dental pulp. Journal of Endodontics. 1982;18:473–475
  4. Yeo IS, Yang JH, Lee JB. In vitro marginal fit of three all-ceramic crown systems. Journal of Prosthetic Dentistry. 2003;90:459–464
  5. Gavelis JR, Morency JD, Riley ED, Sozio RB. The effect of various finish line preparations on the marginal seal and occlusal seat of full crown preparations. Journal of Prosthetic Dentistry. 1981;45:138–145
  6. Jorgensen KD. Factors affecting the film thickness of zinc phosphate cements. Acta Odontologica Scandinavica. 1960;18:479
  7. Eames WB, O’Neal SJ, Monteiro J, Miller C, Roan JD, Cohen KS. Techniques to improve the seating of castings. Journal of the American Dental Association. 1978;96:432
  8. Schwartz IS. A review of methods and techniques to improve the fit of cast restorations. Journal of Prosthetic Dentistry. 1986;56:279–283
  9. White SN, Yu Z. Film thickness of new adhesive luting agents. Journal of Prosthetic Dentistry. 1992;67:782–785
  10. Mitchell CA, Pintado MR, Douglas WH. Nondestructive, in vitro quantification of crown margins. Journal of Prosthetic Dentistry. 2001;85:575–584
  11. Beschnidt SM, Strub JR. Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth. Journal of Oral Rehabilitation. 1999;26:582–593
  12. Goldin EB, Boyd NW, Goldstein GR, Hittelman EL, Thompson VP. Marginal fit of leucite–glass pressable ceramic restorations and ceramic-pressed-to-metal restorations. Journal of Prosthetic Dentistry. 2005;93:143–147
  13. Wilson PR. Effect of increasing cement space on cementation of artificial crowns. Journal of Prosthetic Dentistry. 1994;71:560–564
  14. Sulaiman F, Chai J, Jameson LM, Wozniak WT. A comparison of the marginal fit of In-Ceram IPS Empress and Procera crowns. International Journal of Prosthodontics. 1997;10:478–484
  15. Fleming GJR, Dobinson MM, Landini G, Harris JJ. An in-vitro investigation of the accuracy of fit of Procera and Empress crowns. European Journal of Prosthodontics and Restorative Dentistry. 2005;13:109–114
  16. Heintze SD, Cavalleri A, Forjanic M, Zellweger G, Rousson V. A comparison of three different methods for the quantification of the in vitro wear of dental materials. Dental Materials. 2006;22:1051–1062
  17. Resin reinforced glass ionomer cements. CRA Newsletter 1996;11:3.
  18. Resin ionomer luting cements. Reality Now 1995;68:1–2.
  19. Kanchanavasita W, Anstice HM, Pearson GJ. Water sorption characteristics of resin-modified glass-ionomer cements. Biomaterials. 1997;18:343–349
  20. Christensen GJ. Cements used for full crown restorations: a survey of the American academy of esthetic dentistry. Journal of Esthetic Dentistry. 1997;9:20–26
  21. Leevailoj C, Platt JA, Cochran MA, Moore BK. In vitro study of fracture incidence and compressive fracture load of all-ceramic crowns cemented with resin-modified glass ionomer and other luting agents. Journal of Prosthetic Dentistry. 1998;80:699–707
  22. Black S, Amoore JN. Measurement of forces applied during the clinical cementation of dental crowns. Physiological Measurement. 1993;14:387–392
  23. Knobloch LA, Kerby RE, McMillen K, Clelland N. Solubility and sorption of resin-based luting cements. Operative Dentistry. 2000;25:434–440
  24. Watts DC, Kisumbi BK, Toworfe GK. Dimensional changes of resin/ionomer restoratives in aqueous and neutral media. Dental Materials. 2000;16:89–96
  25. Mitchell CA, Pintado MR, Geary L, Douglas WH. Retention of adhesive cement on the tooth surface after crown cementation. Journal of Prosthetic Dentistry. 1999;81:668–677
  26. Good M-L, Orr JF, Mitchell CA. In vitro study of mean loads and modes of failure of all-ceramic crowns cemented with light-cured or dual-cured luting cement, after 1 and 30 d of storage. European Journal of Oral Sciences. 2008;116:83–88
  27. van Dijken JWV, Höglund-Aberg C, Olofsson A-L. Fired ceramic inlays: a 6-year follow up. Journal of Dentistry. 1998;26:219–225
  28. Pintado MR, Anderson GC, DeLong R, Douglas WH. Variation in tooth wear in young adults over a two year period. Journal of Prosthetic Dentistry. 1997;77:313–320
  29. Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. Journal of Prosthetic Dentistry. 1989;62:405–408
  30. Hayashi M, Wilson NHF, Ebisu S, Watts DC. Influence of explorer tip diameter in identifying restoration margin discrepancies. Journal of Dentistry. 2005;33:669–674
  31. McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. British Dental Journal. 1971;131:107–111
  32. Piwowarczyk A, Lauer H-C. Mechanical properties of luting cements after water storage. Operative Dentistry. 2003;28:535–542
  33. Kumbuloglu O, Lassila LVJ, User A, Vallittu PK. A study of the physical and chemical properties of four resin composite luting cements. International Journal of Prosthodontics. 2004;17:357–363
  34. Piwowarczyk A, Windmueller B, Lauer H-C, Mahler A. In-vitro study of the mechanical properties of luting cements. Journal of Dental Research. 2002;81:413;Abstract 3342
  35. Rosentritt M, Behr M, Lang R, Handel G. Influence of cement type on the marginal adaptation of all-ceramic MOD inlays. Dental Materials. 2004;20:463–469
  36. Janda R, Roulet J-F, Latta M, Rüttermann S. Water sorption and solubility of contemporary resin-based filling materials. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 2007;82B:545–551
  37. Ito S, Hashimoto M, Wadgaonkar B, Svizero N, Carvalho RM, Yiu C, et al. Effects of resin hydrophilicity on water sorption and changes in modulus of elasticity. Biomaterials. 2005;26:6449–6459
  38. Tay FR, King NM, Chan K-M, Pashley DH. How can nanoleakage occur in self-etching adhesive systems that demineralize and infiltrate simultaneously?. Journal of Adhesive Dentistry. 2002;4:255–269
  39. Isodor F, Bröndum K. A clinical evaluation of porcelain inlays. Journal of Prosthetic Dentistry. 1995;74:140–144
  40. Rueggeberg FA, Caughman WF. The influence of light exposure on polymerization of dual-cure resin cements. Operative Dentistry. 1993;18:48–55
  41. Korolev G, Berlin A. Polymerization in highly viscous media and three dimensional polymerisation. III. The mechanism of auto-acceleration in the initial and middle stages of the polymerization of polyester-acrylates. Polymer Science USSR. 1963;4:500–506
  42. Hermesch CB, Wall BS, McEntire JF. Dimensional stability of dental restorative materials and cements over four years. General Dentistry. 2003;518–523
  43. Cattani-Lorente M-A, Dupuis V, Payan J, Moya F, Meyer J-M. Effect of water on the physical properties of resin-modified glass ionomer cements. Dental Materials. 1999;15:71–78
  44. Diaz-Arnold AM, Vargas MA, Haselton DR. Current status of luting agents for fixed prosthodontics. Journal of Prosthetic Dentistry. 1999;81:135–141
  45. Sindel J, Frankenberger R, Krämer N, Petschelt A. Crack formation of all-ceramic crowns dependent on different core build-up and luting materials. Journal of Dentistry. 1999;27:175–181
  46. van Dijken JWV. Resin-modified glass ionomer cement and self-cured resin composite luted ceramic inlays. A 5-year clinical evaluation. Dental Materials. 2003;19:670–674
  47. De Munck J, Van Meerbeek B, Yoshida Y, Inoue S, Vargas M, Suzuki K, et al. Four-year water degradation of total-etch adhesives bonded to dentin. Journal of Dental Research. 2003;82:136–140
  48. Groten M, Axmann D, Pröbster L, Weber H. Determination of the minimum number of marginal gap measurements required for practical in vitro testing. Journal of Prosthetic Dentistry. 2000;83:40–49

PII: S0300-5712(08)00262-5

doi: 10.1016/j.jdent.2008.09.011

Journal of Dentistry
Volume 37, Issue 1 , Pages 65-75 , January 2009