Journal of Dentistry
Volume 35, Issue 11 , Pages 819-826 , November 2007

An overview of zirconia ceramics: Basic properties and clinical applications

Received 21 February 2007 ,Revised 17 July 2007 ,Accepted 19 July 2007.

References 

  1. Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials. 1999;20:1–25
  2. Garvie RC, Hannink RH, Pascoe RT. Ceramic steel?. Nature. 1975;258:703–704
  3. Gupta TK, Bechtold JH, Kuznickie RC, Cadoff LH, Rossing BR. Stabilization of tetragonal phase in polycrystalline zirconia. Journal of Materials Science. 1978;13:1464
  4. Garvie RC, Nicholson PS. Structure and thermodynamical properties of partially stabilized zirconia in the CaO-ZrO2 system. Journal of American Ceramic Society. 1972;55:152–157
  5. Helmer JD, Driskell TD. Research on bioceramics. In: Symposium on Use of Ceramics as Surgical Implants. South Carolina, USA: Clemson University; 1969;
  6. Hulbert SF, Morrison SJ, Klawitter JJ. Tissue reaction to three ceramics of porous and non-porous structures. Journal of Biomedical Materials Research. 1972;6:347–374
  7. Garvie RC, Urbani C, Kennedy DR, Mcneuer JC. Biocompatibility of magnesia partially stabilized zirconia (Mg-Psz) ceramics. Journal of Materials Science. 1984;19:3224–3228
  8. Wagner W, Rixecker H, Wahlmann UW. Morphometric comparison of histologic bone reactions after implantation of mono- and polycrystalline alluminium oxide pins. In:  Christel P,  Meunier A,  Lee AJC editor. Biological and Biomechanical Performance of Biomaterials. Amsterdam, The Netherlands: Elsevier; 1986;p. 129–134
  9. Christel P, Meunier A, Heller M, Torre JP, Peille CN. Mechanical properties and short-term in-vivo evaluation of yttrium-oxide-partially-stabilized zirconia. Biomedical Materials Research. 1989;23:45–61
  10. Maccauro G, Specchia N, Arena M, Piconi C, Greco F. Biological response to calcia-partially stabilised zirconia ceramics. In: 8th Esb Meeting. Rome, Italy. 1992;p. 110
  11. Piconi C, Burger W, Richter HG, Cittadini A, Maccauro G, Covacci V, et al. Y-TZP ceramics for artificial joint replacements. Biomaterials. 1998;19:1489–1494
  12. Bukat A, Fassina P, Greco F, Piantelli S, Piconi C, Zaghini C. GSP-made Ca-PSZ for Biomedical Applications. In: 3rd Symposum on ceramics in medicine. Terre Haute, USA. 1990;
  13. Dion I, Bordenave L, Levebre F. Physico-chemistry and cytotoxicity of ceramics. Journal of Materials Science: Materials in Medicine. 1994;5:18–24
  14. Torricelli P, Verne E, Brovarone CV, Appendino P, Rustichelli F, Krajewski A, et al. Biological glass coating on ceramic materials: in vitro evaluation using primary osteoblast cultures from healthy and osteopenic rat bone. Biomaterials. 2001;22:2535–2543
  15. Lohmann CH, Dean DD, Koster G, Casasola D, Buchhorn GH, Fink U, et al. Ceramic and PMMA particles differentially affect osteoblast phenotype. Biomaterials. 2002;23:1855–1863
  16. Greco F, Piantelli S, Maccauro G, Arena M, Piconi C. Risposta biologica ai materiali ceramici: risultati delle prove in vitro ed in vivo. Minerva Ortopedica Traumatologica. 1993;44:913–917
  17. Catelas I, Petit A, Zukor DJ, Marchand R, Yahia L, Huk OL. Induction of macrophage apoptosis by ceramic and polyethylene particles in vitro. Biomaterials. 1999;20:625–630
  18. Silva VV, Lameiras FS, Lobato ZI. Biological reactivity of zirconia-hydroxyapatite composites. Journal of Biomedical Materials Research. 2002;63:583–590
  19. Covacci V, Bruzzese N, Maccauro G, Andreassi C, Ricci GA, Piconi C, et al. In vitro evaluation of the mutagenic and carcinogenic power of high purity zirconia ceramic. Biomaterials. 1999;20:371–376
  20. Warashina H, Sakano S, Kitamura S, Yamauchi KI, Yamaguchi J, Ishiguro N, et al. Biological reaction to alumina, zirconia, titanium and polyethylene particles implanted onto murine calvaria. Biomaterials. 2003;24:3655–3661
  21. Degidi M, Artese L, Scarano A, Perrotti V, Gehrke P, Piattelli A. Inflammatory infiltrate, microvessel density, nitric oxide synthase expression, vascular endothelial growth factor expression, and proliferative activity in peri-implant soft tissues around titanium and zirconium oxide healing caps. Journal of Periodontology. 2006;77:73–80
  22. Carinci F, Pezzetti F, Volinia S, Francioso F, Arcelli D, Farina E, et al. Zirconium oxide: analysis of MG63 osteoblast-like cell response by means of a microarray technology. Biomaterials. 2004;25:215–228
  23. Cales B, Stefani Y. Mechanical properties and surface analysis of retrieved zirconia femoral hip joint heads after an implantation time of two to three years. Journal of Materials Science: Materials in Medicine. 1994;5:376–380
  24. Swab JJ. Low temperature degradation of Y-TZP materials. Journal of Materials Science. 1991;26:6706–6714
  25. Luthardt RG, Holzhuter M, Sandkuhl O, Herold V, Schnapp JD, Kuhlisch E, et al. Reliability and properties of ground Y-TZP-zirconia ceramics. Journal of Dental Research. 2002;81:487–491
  26. Kosmac T, Oblak C, Jevnikar P, Funduk N, Marion L. The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic. Dental Materials. 1999;15:426–433
  27. Jung RE, Sailer I, Hammerle CHF, Attin T, Schmidlin P. In vitro color changes of soft tissues caused by restorative materials. International Journal of Periodontics and Restorative Dentistry. 2007;27:251–257
  28. Raigrodski AJ. Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature. Journal of Prosthetic Dentistry. 2004;92:557–562
  29. Luthy H, Filser F, Loeffel O, Schumacher M, Gauckler LJ, Hammerle CH. Strength and reliability of four-unit all-ceramic posterior bridges. Dental Materials. 2005;21:930–937
  30. Tinschert J, Natt G, Mohrbotter N, Spiekermann H, Schulze KA. Lifetime of alumina- and zirconia ceramics used for crown and bridge restorations. Journal of Biomedical Materials Research. Part B: Applied Biomaterials. 2007;80:317–321
  31. Oh WS, Anusavice KJ. Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures. Journal of Prosthetic Dentistry. 2002;87:536–542
  32. Studart AR, Filser F, Kocher P, Gauckler LJ. Fatigue of zirconia under cyclic loading in water and its implications for the design of dental bridges. Dental Materials. 2007;23:106–114
  33. Gamborena I, Blatz MB. A clinical guidelines to predictable esthetics with Zirconium oxide Ceramic restorations. Quintessence of Dental Technology. 2006;29:11–23
  34. Piwowarczyk A, Ottl P, Lauer HC, Kuretzky T. A clinical report and overview of scientific studies and clinical procedures conducted on the 3M ESPE Lava All-Ceramic System. Journal of Prosthodontic. 2005;14:39–45
  35. Potiket N, Chiche G, Finger IM. In vitro fracture strength of teeth restored with different all-ceramic crown systems. Journal of Prosthetic Dentistry. 2004;92:491–495
  36. Coli P, Karlsson S. Fit of a new pressure-sintered zirconium dioxide coping. Journal of Prosthodontic. 2004;17:59–64
  37. Larsson C, Vult von Steyern P, Sunzel B, Nilner K. All-ceramic two- to five-unit implant-supported reconstructions. A randomized, prospective clinical trial. Swedish Dental Journal. 2006;30:45–53
  38. McLaren EA, Giordano RA. Zirconia-based ceramics: material properties, esthetics and layering techniques of a new veneering porcelain, VM9. Quintessence of Dental Technology. 2005;28:99–112
  39. Goodacre CJ, Campagni WV, Aquilino SA. Tooth preparations for complete crowns: an art form based on scientific principles. Journal of Prosthetic Dentistry. 2001;85:363–376
  40. McLaren EA, White SN. Glass-infiltrated zirconia/alumina-based ceramic for crowns and fixed partial dentures. Practical Periodontics Aesthetic Dentistry. 1999;11:985–994
  41. McLaren EA, Terry DA. CAD/CAM systems, materials, and clinical guidelines for all-ceramic crowns and fixed partial dentures. Compendium of Continuing Education in Dentistry. 2002;23:637–641
  42. Witowski S. (CAD-)/CAM in dental technology. Quintessence of Dental Technology. 2005;28:169–184
  43. Sorensen JA. The Lava system for CAD/CAM production of high strenght precision fixed prosthodontics. Quintessence of Dental Technology. 2003;26:57–67
  44. Sundh A, Sjogren G. A comparison of fracture strength of yttrium-oxide- partially-stabilized zirconia ceramic crowns with varying core thickness, shapes and veneer ceramics. Journal of Oral Rehabilitation. 2004;31:682–688
  45. Sundh A, Sjogren G. Fracture resistance of all-ceramic zirconia bridges with differing phase stabilizers and quality of sintering. Dental Materials. 2006;22:778–784
  46. Aboushelib MN, de Jager N, Kleverlaan CJ, Feilzer AJ. Effect of loading method on the fracture mechanics of two layered all-ceramic restorative systems. Dental Materials. 2007;23:952–959
  47. Aboushelib MN, Kleverlaan CJ, Feilzer AJ. Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II: Zirconia veneering ceramics. Dental Materials. 2006;22:857–863
  48. Bindl A, Luthy H, Mormann WH. Thin-wall ceramic CAD/CAM crown copings: strength and fracture pattern. Journal of Oral Rehabilitation. 2006;33:520–528
  49. Derand P, Derand T. Bond strength of luting cements to zirconium oxide ceramics. International Journal of Prosthodontic. 2000;13:131–135
  50. Palacios RP, Johnson GH, Phillips KM, Raigrodski AJ. Retention of zirconium oxide ceramic crowns with three types of cement. Journal of Prosthetic Dentistry. 2006;96:104–114
  51. Blatz MB, Sadan A, Martin J, Lang B. In vitro evaluation of shear bond strengths of resin to densely-sintered high-purity zirconium-oxide ceramic after long-term storage and thermal cycling. Journal of Prosthetic Dentistry. 2004;91:356–362
  52. Atsu SS, Kilicarslan MA, Kucukesmen HC, Aka PS. Effect of zirconium-oxide ceramic surface treatments on the bond strength to adhesive resin. Journal of Prosthetic Dentistry. 2006;95:430–436
  53. Kern M, Wegner SM. Bonding to zirconia ceramic: adhesion methods and their durability. Dental Materials. 1998;14:64–71
  54. Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H. Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study. International Journal of Prosthodontic. 2001;14:231–238
  55. Sundh A, Molin M, Sjogren G. Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing. Dental Materials. 2005;21:476–482
  56. Att W, Grigoriadou M, Strub JR. ZrO2 three-unit fixed partial dentures: comparison of failure load before and after exposure to a mastication simulator. Journal of Oral Rehabilitation. 2007;34:282–290
  57. Chevalier J. What future for zirconia as a biomaterial?. Biomaterials. 2006;27:535–543
  58. Yildirim M, Edelhoff D, Hanisch O, Spiekermann H. Ceramic abutments—a new era in achieving optimal esthetics in implant dentistry. International Journal of Periodontics Restorative Dentistry. 2000;20:81–91
  59. Vigolo P, Fonzi F, Majzoub Z, Cordioli G. An in vitro evaluation of ZiReal abutments with hexagonal connection: in original state and following abutment preparation. International Journal of Oral Maxillofacial Implants. 2005;20:108–114
  60. Vigolo P, Fonzi F, Majzoub Z, Cordioli G. An in vitro evaluation of titanium, zirconia, and alumina procera abutments with hexagonal connection. International Journal of Oral Maxillofacial Implants. 2006;21:575–580
  61. Park SW, Driscoll CF, Romberg EE, Siegel S, Thompson G. Ceramic implant abutments: cutting efficiency and resultant surface finish by diamond rotary cutting instruments. Journal of Prosthetic Dentistry. 2006;95:444–449
  62. Glauser R, Sailer I, Wohlwend A, Studer S, Schibli M, Scharer P. Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study. International Journal of Prosthodontics. 2004;17:285–290
  63. Butz F, Heydecke G, Okutan M, Strub JR. Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation. Journal of Oral Rehabilitation. 2005;32:838–843
  64. Scarano A, Piattelli M, Caputi S, Favero GA, Piattelli A. Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study. Journal of Periodontology. 2004;75:292–296
  65. Rimondini L, Cerroni L, Carrassi A, Torricelli P. Bacterial colonization of zirconia ceramic surfaces: an in vitro and in vivo study. International Journal of Oral Maxillofacial Implants. 2002;17:793–798
  66. Kou W, Molin M, Sjogren G. Surface roughness of five different dental ceramic core materials after grinding and polishing. Journal of Oral Rehabilitation. 2006;33:117–124
  67. Edelhoff D, Sorensen JA. Tooth structure removal associated with various preparation designs for posterior teeth. International Journal of Periodontics and Restorative Dentistry. 2002;22:241–249
  68. Edelhoff D, Veber V. Inlay retained fixed partial denture using CAD/CAM zirconium dioxide ceramic frameworks: a case report. Quintessence of Dental Technology. 2004;27:91–99
  69. Kohal RJ, Klaus G. A zirconia implant-crown system: a case report. International Journal of Periodontics Restorative Dentistry. 2004;24:147–153
  70. Scarano A, Di Carlo F, Quaranta M, Piattelli A. Bone response to zirconia ceramic implants: an experimental study in rabbits. Journal of Oral Implantology. 2003;29:8–12
  71. Sennerby L, Dasmah A, Larsson B, Iverhed M. Bone tissue responses to surface-modified zirconia implants: A histomorphometric and removal torque study in the rabbit. Clinical Implant Dentistry and Related Research. 2005;7:S13–S20
  72. Bianchi AE, Bosetti M, Dolci G, Sberna MT, Sanfilippo F, Cannas M. In vitro and in vivo follow-up of titanium transmucosal implants with a zirconia collar. Journal of Applied Biomaterials & Biomechanic. 2004;2:143–150
  73. Kohal RJ, Klaus G, Strub JR. Zirconia-implant-supported all-ceramic crowns withstand long-term load: a pilot investigation. Clinical Oral Implants Research. 2006;17:565–571
  74. Suarez MJ, Lozano JF, Paz Salido M, Martinez F. Three-year clinical evaluation of In-Ceram Zirconia posterior FPDs. International Journal of Prosthodontic. 2004;17:35–38
  75. Raigrodski AJ, Chiche GJ, Potiket N, Hochstedler JL, Mohamed SE, Billiot S, et al. The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. Journal of Prosthetic Dentistry. 2006;96:237–244
  76. Sailer I, Feher A, Filser F, Luthy H, Gauckler LJ, Scharer P, et al. Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up. Quintessence International. 2006;37:685–693
  77. Pjetursson BE, Sailer I, Zwahlen M, Hammerle CHF. A systematic review of the survival and compication rates of all-ceramic and metal ceramic reconstructions after an observation period of at least 3 years. Part I: single crowns. Clinical Oral Implant Research. 2007;18:73–85
  78. Sailer I, Pjetursson BE, Zwahlen M, Hammerle CHF. A systematic review of the survival and compication rates of all-ceramic and metal ceramic reconstructions after an observation period of at least 3 years. Part II: fixed dental prostheses. Clinical Oral Implant Research. 2007;18:86–96

PII: S0300-5712(07)00141-8

doi: 10.1016/j.jdent.2007.07.008

Journal of Dentistry
Volume 35, Issue 11 , Pages 819-826 , November 2007