Journal of Dentistry
Volume 35, Issue 6 , Pages 509-512, June 2007

The intra/inter-examiner reproducibility of the new DIAGNOdent Pen on occlusal sites

  • Jan Kühnisch

      Affiliations

    • Corresponding Author InformationCorresponding author at: Ludwig-Maximilians-Universität München, Poliklinik für Zahnerhaltung und Parodontologie, Goethestraße 70, 80336 München, Germany. Tel.: +49 89 51609343; fax: +49 89 51609302.
  • ,
  • Katharina Bücher
  • ,
  • Reinhard Hickel

Ludwig-Maximilians-University of Munich, Department of Conservative Dentistry and Periodontology, Munich, Germany

Received 28 September 2006; received in revised form 30 January 2007; accepted 4 February 2007.

Abstract 

Objective

This in vitro study on occlusal sites aimed to assess the intra/inter-examiner reproducibility of the new DIAGNOdent Pen (KaVo, Biberach, Germany) and to prove the assumption that its handling is easy to learn by dental students.

Methods

Two hundred and forty-one sites of 90 occlusal non-cavitated molar surfaces were investigated twice by 2 dentists and 2 undergraduate students with the DIAGNOdent Pen according to manufacturer's instructions. Intra/inter-examiner reproducibility was assessed calculating intra-class correlation coefficients (ICCs) and the range of the 95% limits of agreement by Bland and Altman.

Results

Intra-examiner reproducibility revealed excellent ICCs (0.84–0.92); but the range amounted to 41.2–59.1, which indicate a wide measuring range. The inter-examiner reproducibility using all measurements had to be proved as excellent (ICC 0.84); the range was found in the same order of magnitude as mentioned above (53.2). When measurements were categorised according to treatment related cut-offs a good inter-examiner reproducibility was detected in the interval of <30 (ICC 0.70); an excellent ICC were registered for the interval >30 (ICC 0.51). For both intervals the range values (<30: range 32.3 and >30: range 67.7) exceeded a deviation limit of ±20%. Both students tended to measure slightly more precise compared to the dentists.

Conclusions

This study revealed a wide measuring range of DIAGNOdent Pen readings. Since there were no differences between dentists and students it can be used as adjunct tool by undergraduates as well. Nevertheless, based on the registered reproducibility the DIAGNOdent Pen should be used additionally to visual inspection and dental radiographs.

Keywords: Dental caries, Pits and fissures, Diagnosis, Reproducibility, DIAGNOdent, Laser fluorescence

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0300-5712(07)00031-0

doi:10.1016/j.jdent.2007.02.001

Journal of Dentistry
Volume 35, Issue 6 , Pages 509-512, June 2007