Journal of Dentistry
Volume 35, Issue 5 , Pages 416-424, May 2007

Resin strengthening of dental ceramics—The impact of surface texture and silane

  • Owen Addison

      Affiliations

    • Biomaterials Unit, University of Birmingham, School of Dentistry, St. Chad's Queensway, Birmingham B4 6NN, United Kingdom
    • Corresponding Author InformationCorresponding author. Tel.: +44 121 237 2911; fax: +44 121 237 2932.
  • ,
  • Peter M. Marquis

      Affiliations

    • Biomaterials Unit, University of Birmingham, School of Dentistry, St. Chad's Queensway, Birmingham B4 6NN, United Kingdom
  • ,
  • Garry J.P. Fleming

      Affiliations

    • Materials Science Unit, Division of Oral Biosciences, Dublin Dental School & Hospital, Trinity College Dublin, Dublin 2, Ireland

Received 28 July 2006; received in revised form 20 November 2006; accepted 27 November 2006.

Abstract 

Objectives

To examine the effect of porcelain surface texture achieved utilising three clinically relevant surface preparation methods prior to silane and unfilled resin application on the flexure strength of a low fusing feldspathic porcelain.

Materials and methods

Five hundred and forty dentine disc-shaped specimens (15.0mm diameter and 0.9mm thickness) were condensed, fired and allocated to 18 groups. Six groups were stored as-fired, six were alumina abraded and six were acid-etched. Samples were coated with silane, unfilled resin or both prior to bi-axial flexure testing. Group means were compared utilising a three factor design general linear model and post hoc all paired Tukey tests at P<0.05. Weibull analysis was employed to examine the reliability of the strength data. Profilometry was used to characterise the surface texture of the specimen surfaces.

Results

Alumina abraded and acid-etched specimens had significantly lower flexure strengths than the as-fired specimens. A significant difference between the degree of strengthening observed following unfilled resin application on the three surface texture investigated was observed (P<0.001). Silane application prior to resin coating resulted in no further significant increases in the mean bi-axial flexure strengths of the three surface textures. The as-fired surfaces had a low frequency of irregular amplitude defects, alumina abraded surfaces had an increased frequency of regular amplitude defects whilst the acid-etched surface consisted of an increased frequency of irregular amplitude defects.

Conclusion

The strengthening mechanism whilst dependent on surface texture was independent of defect severity. No significant strengthening occurred following silane priming suggesting that, for the unfilled resin utilised, the strengthening mechanism was not enhanced by improved resin-ceramic adhesion.

Keywords: Feldspathic porcelain, Bi-axial flexure strength, Surface texture, Silane, Unfilled resin

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0300-5712(06)00226-0

doi:10.1016/j.jdent.2006.11.012

Journal of Dentistry
Volume 35, Issue 5 , Pages 416-424, May 2007