Journal of Dentistry
Volume 32, Issue 3 , Pages 247-254, March 2004

The effect of light-curing modes on the microleakage of cervical resin composite restorations

Division of Cariology, Department of Developmental and Reconstructive Medicine, Course of Medical and Dental Sciences, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1, Sakamoto, Nagasaki 852-8588, Japan

Received 28 May 2003; received in revised form 9 October 2003; accepted 28 November 2003.

Abstract 

Objective. This study investigated the effect of light-curing modes on the microleakage of cervical resin composite restorations.

Methods. Eighty wedge-shaped cervical cavities, C-factor approximately 1.3, were prepared on the labial surface of bovine incisors. The cavities were treated with a two-step experimental self-etching primer adhesive system containing an antibacterial monomer (ABF), according to the manufacturer's instructions, and filled with a single increment of a hybrid resin composite. The restorations were allocated randomly into four groups of 20: Group 1—the restorations were light-cured for 40 s with a conventional light-curing unit (New Light VL-II); Group 2—the restorations were cured with Candelux using a two-step mode; Group 3—the restorations were cured with Astralis 7 using a ramping mode; Group 4—the restorations were light-cured for 3 s with a plasma arc light-curing unit (Wave Light). Half of the specimens from each group were subjected to thermocycling (5–60 °C, 15 s dwell time, 5000 cycles) prior to immersion in 0.5% basic fuchsin. The teeth were sectioned and the degrees of dye penetration were scored. The data were analyzed with either the Kruskal–Wallis test or the Mann–Whitney U-test (p<0.05).

Results. No significant differences were found in the microleakage scores among the light-curing modes used. The restorations tended to display more microleakage when they were subjected to thermocycling, but the differences were not statistically significant.

Conclusions. These findings suggest that light-curing modes may have no effect on the microleakage of cervical cavities with a small C-factor, as is the case in this study.

Keywords:  Microleakage, Cervical lesions, Light-curing modes, Rate of polymerization, Polymerization shrinkage stress

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0300-5712(03)00202-1

doi:10.1016/j.jdent.2003.11.005

Journal of Dentistry
Volume 32, Issue 3 , Pages 247-254, March 2004