High-strength ceramics.
Quintessence Int. 1987;18:97–106
-
.
The influence of cements on the mechanical performance of dental ceramics.
Proc Fifth Int Symp Ceram Med, Bioceram. 1992;5:317–324
-
.
Fracture-surface analysis of dental ceramics.
J Prosthet Dent. 1989;62:652–661
- . The influence of clinically induced variability on the bi-axial fracture strength of aluminous core porcelain discs. J Dent. 1999;27:587–594
- . Tensile stresses in glass–ceramic crowns: effect of flaws and cement voids. Int J Prosthodont. 1992;5:351–358
-
.
A tooth for a tooth—ceramics in modern dentistry.
Chem Ind. 1986;657–661
- . Comparison of two heat-pressed all-ceramic dental materials. Dent Mater. 2000;16:389–395
- . A compressive strength study of complete ceramic crowns. Part II. J Prosthet Dent. 1991;65:388–391
- . Fracture strength of full-contoured ceramic crowns and porcelain-veneered crowns of ceramic copings. J Prosthet Dent. 1994;71:462–467
-
Hornberger H. Strength microstructure relationships in a dental alumina glass composite. PhD Thesis, The University of Birmingham; 1995.
-
McLean JW. The development of ceramic oxide reinforced dental porcelains with an appraisal of their physical and chemical properties. MDS Thesis, University of London; 1966.
-
.
Seven year results of leucite-reinforced glass–ceramic crowns.
J Dent Res. 1998;77:802;
Abstr. No. 1369
- . Survival of Dicor glass–ceramic dental restorations over 14 years: Part I. Survival of Dicor complete coverage restorations and effect of internal surface acid etching, tooth position, gender, and age. J Prosthet Dent. 1999;81:23–32
- . Clinical examination of leucite reinforced glass–ceramic crowns (Empress) in general practise: a retrospective study. Int J Prosthodont. 1999;12:122–128
- . Fracture surface characterization of clinically failed all-ceramic crowns. J Dent Res. 1994;73:1824–1832
- . The influence of clinically induced variability on the bi-axial fracture strength of cemented aluminous core porcelain discs. Dent Mater. 1999;15:62–70
-
.
The effect of cement type and mixing on the bi-axial fracture strength of cemented aluminous core porcelain discs.
Dent Mater. 2002;
in press
-
.
Effect of surface roughness on the Weibull distribution of porcelain strength.
J Dent Res. 1997;76:419;
Abstr. No. 3248
-
.
Journal of Dental Research. 2001;79:557;
Abstr. No. 247
- . Measurement of tensile strength of dental restorative materials by use of a diametral compression test. J Dent Res. 1971;50:436–442
-
.
An analysis of the diametral-compression test.
Mater Res Standards. 1963;3:283–289
-
.
Comments on an indirect tensile test on concrete cylinders.
Mag Concrete Res. 1955;1:87–96
- . The tensile and compressive strength of plaster and stone. Aust Dent J. 1966;11:415–422
- . Effect of firing temperature and water exposure on crack propagation in unglazed porcelain. J Dent Res. 1989;68:1075–1081
-
.
Theory of plates and shells. 2nd ed.
Theory of plates and shells. 1959;
Chapter 3, p. 51–78
- . Comparative evaluation of ceramic-metal bond tests using finite element analysis. J Dent Res. 1980;59:608–613
-
.
A statistical distribution function of wide applicability.
J Appl Mech. 1951;18:293–297
-
.
On estimating the Weibull modulus for a brittle material.
J Mater Sci. 1979;14:1080–1084
-
.
The statistical approach to engineering design in ceramics.
Proc Br Ceram Soc. 1973;22:429–452
-
.
An engineer's approach to the prediction of failure probability in brittle components.
Proc Br Ceram Soc. 1973;22:453–487
-
.
Statistical reproducibility of the dynamic and static fatigue experiments.
Ceram Bull. 1981;60:798–806
- . Ceramics in dentistry: historical roots and current perspectives. J Prosthet Dent. 1996;75:18–32
-
.
A numerical study on the application of the Weibull theory to brittle materials.
Engng Fracture Mech. 2001;68:1171–1179
-
.
Biaxial and uniaxial data for statistical comparison of a ceramic's strength.
J Am Ceram Soc. 1979;62:510–515
- . Influence of test method on failure stress of brittle materials. J Dent Res. 1990;69:1791–1799
- . Effect of loading conditions on bi-axial flexure strength of dental cements. Dent Mater. 1992;8:100–104
- . The mechanical strength and microstructure of all-ceramic crowns. J Dent. 1987;15:153–158
-
.
Appraisal of biaxial flexure strength testing.
J Non-Cryst Solids. 1980;38&39:419–424
-
.
Biaxial flexure tests for ceramics.
Am Ceram Soc Bull. 1980;59:1193–1197
-
.
Symmetrical bending of thin circular elastic plates of equally spaced point supports.
J Res Natl Bureau Standards. 1967;71:1–10
-
.
Ball-on-ring test revisited.
J Am Ceram Soc. 1989;72:1538–1541
PII: S0300-5712(02)00012-X